ICM Furnace Control Replaces Carrier LH33WP003 & LH33WP003A

ICM Furnace Control Replaces Carrier LH33WP003 & LH33WP003A

ICM
Item ID: ICM291

  • Direct Spark Ignition (DSI) Control Board
  • Microprocessor-Based
  • Controls Combustion, Blower and Indoor Motors; Spark Ignitor and the Gas Valve
  • Monitors Timing, Trial for Ignition, Flame Sensing and Lockout
  • 100% Lockout Safety Feature
  • Compatible with LP or Natural Gas
  • Status LED for Fault Codes to Aid in Troubleshooting
  • Power cons: 0.3A plus gas valve current @ 24 VAC
  • Timing:
  • Pre-purge: 45 seconds
  • Trial for Ignition: 5+2 seconds
  • Retry period: Every 20 seconds for
    • 15 minutes
    • Lockout: manual reset
    • Post-purge: 45 seconds
  • Inputs:
    • Power: RT and C
    • Thermostat interface: R, W and G
    • Safety switches: RS, LS, and CS
    • Combustion motor Hall Effect
    • sensor
    • Flame sensing
  • Outputs:
    • Spark
    • Gas Valve: GV
    • Combustion motor: CM
    • Blower motor: BM
    • Indoor fan motor: IFO
  • LED indicators:
  • Red LED:
    • Steady ON- normal operation
    • Flashing – fault codes

Calif Prob 65 Warning
Calif Prob 65 Warning
Brand ICM
Country of Origin USA
Switches Safety switches: RS, LS, and CS
Timings Timing|Pre-purge: 45 seconds|Trial for Ignition: 5+2 seconds|Retry period: Every 20 sec. for 5 min.|Lockout: manual reset|Post-purge: 45 seconds
UPC 800442011844
Carrier 3A
Carrier LH33WP003