ENVIRONMENT
• Ambient Temperature
• Operating: -40°F to 176°F
• Storage: -40°F to 185°F
• Humidity: 5% to 95% R.H. (non-condensing) @ +55°F
ELECTRICAL
• Voltage Range: Line (98 to 132 VAC) @ 60Hz
• Ignitor: 5A @ 120 VAC
• Cool Blower: 10 HP, 120 VAC
• Low Heat: 5A, 1/2 HP, 120 VAC
• High Heat: 10A, 1 HP, 120 VAC
• Inducer Motor: 4A, FLA-8.0 LRA @ 120 VAC
• Gas Valve: 1.5A @ 30 VAC
• EAC: 1A@120 VAC
• Humidifier: 0.5A & 24 VAC
• Controls gas valve, ignitor, blower motor, inducer,
humidifier and air cleaner
• Microprocessor-based precision
• Designed for 100% gas shutoff in case of ignition
failure
• Twinning compatible with another ICM2807 control
• Reverse polarity protection
• Secondary brownout voltage protection
• Compatible with 24 VAC standard thermostat
• Continuous Blower Speed Jumper
• Limit Switch Lockout Time
• Limit Switch Lockout After Power Interruption
• Self-Diagnostics
• Provides diagnostic LEDs to aid in troubleshooting