Every effort has been made to insure the accuracy of product data and cross reference information. Design changes may result in different operating characteristics or dimensional changes from one manufacturer to another. Therefore, Packard cannot accept responsibility for the ultimate selection. For additional information, please contact Packard

×
*Disclaimer                            Use the Product Selector Tool

ICM FURNACE CONTROL

  • Universal intermittent pilot gas ignition control
  • Provides ignition sequence, flame monitoring and safety shutoff for single/dual rod intermittent pilot control applications
  • For gas fired furnaces, boilers and other heating appliances
  • Switch selectable pre-purge and ignition trial times with permanent lock
  • Works with or without vent damper connected
  • Works with both Natural & LP gas systems
  • Anticipator setting: 0.3A plus valve load @ 24 VAC
  • Trial for ignition: 15 or 90 seconds (switch selectable)
  • LEDs:
    • Green status LED provides system status and error codes
    • Yellow flame LED indicates flame presence & flame strength
  • Relative humidity: 0% to 95% non-condensing
Control Voltage Line 24V (18-30 VAC), 50-60 Hz
Operating Temp. °F -40°F to 176°F
Honeywell S8610U3009